Steam boiler plant

Multiple system

Strong team performance

Steam output

Up to 16.000 kg/h

Combustion

Oil / gas, electric
CERTUSS multiple system 2x Universal TC - vapour on demand

Powerful multiple system for higher and variable steam requirements

The variable cascade connection system

Increasing steam output: Should the steam demand be high, e.g. 16,000 kg/h, we can connect multiple steam generators together in series for you. Whether it's 2, 3, 4 or more combined boilers totally depends on your steam supply requirements.

More economical than a single large steam boiler: With a multiple steam boiler plant from CERTUSS, you'll benefit from highly flexible steam supply and efficient operation through a cascade connection. The integrated diagnostic system variably distributes the steam supply to the base-load boiler and the peak-load boiler. For example, two steam generators in a triple system handle the base load. The third rapid steam generator switches on during peak-load times.

Integrated redundancy: The consequent cut-in of a steam generator which is ready for operation is also possible when maintenance is to be performed on an active steam generator. The switched-on boiler functions as a redundant boiler (reserve boiler). Downtimes can be reduced considerably in this way. Load distribution enables even distribution of operating hours for each boiler.

Compatible: Multiple steam boiler plants from CERTUSS are available in all sizes and combustion types – for gas- or oil-combustion UNIVERSAL or JUNIOR steam boilers and for the ELEKTRO series as well. CERTUSS steam generators of different types can be combined together.

More vapour output through series connection

Integrated online control system

In multiple systems, each individual steam generator can be controlled online using the building control system. This saves resources.

Highly efficient output adjustment

A consistently high degree of combustion-related efficiency is achieved across all output levels regardless of the steam demand.

Significantly smaller space requirement

With CERTUSS steam generators, you can achieve double the steam output compared to steam boilers for a specified boiler house size.

Our boiler is already steaming here

Steam Generator for Accra Brewery, Ghana

For Accra Brewery Limited (ABL) in Ghana, CERTUSS is installing a new steam boiler system for its brewery operations. The task is to replace an older 16-t/h shell boiler with an operationally reliable and energy-efficient plant with a steam output of 16 t/h.

CERTUSS installs a turnkey solution – consisting of a multiple plant with eight UNIVERSAL TC 2000 steam generators and two CERTUSS supply units CVE. Due to its significantly lower water volume compared to the old shell boiler, the new multiple plant has considerably more operational safety…

Read more

Informational material

Get advice from our experts